Field of Utilization: Clinics and Small Hospitals
- Microwave induced Sterilization Process (Optional)
- Pressure container built of high-quality Stainless Steel
- Design and production certified by TUV Austria
- Produced according to EU Directives PED (2014/68/EU) 2006/42/EC, 2014/30/EU & EU Norms EN285
- Sophisticated automation control system with advanced reporting and monitoring software
- Online access via the internet for supervision and troubleshooting
- Fully automatic operation- no need for any operator intervention
- Automatic elevator system for easy loading (Optional)
- No water consumption
- Low fuel and electrical consumption for integrated steam boilers equipped with state of the art steam regeneration system
- Vacuum Pump
- Odor Control System (Optional)
STERILIZATION - MICROWAVE PROCESS
Loading
At the beginning of the cycle , once the upper lid opens, the operator loads the waste in the loading chamber.
Shredding / Microwave
The shredder, controlled by the PLC, changes rotation direction due to the “anti blocking” capability that prevents the blades to get jammed. Durring the shredding process the waste is treated with microwave generated by 6 integrated magnetron units (Optional)
Our special design shredder is capable of grinding very hard materials like surgical stainless steel instruments and hard ceramics.
Heating / Sterilization
Heating is achieved by injecting saturated steam until the homogeneous temperature in the upper and lower chamber reaches 134°C (274 F). Sterilization is completed by maintaining 134°C (274 F) – 138 °C (280 F) temperature and equivalent pressure for a period of 10 – 15 minutes.
These factors provide the possibility to decrease the pathogenic contamination level in the medical waste by 8 Log 10 valu
Cooling and Draining
Excess steam in the chamber is removed during cooling phase and the temperature of the grinded sterilized waste is lowered to by injecting cold air in the chamber of the autoclave.
The condensed water, that sterile and can be safely discharged into the sewage system is drained with the help of positive pressure or vacuum.
Unloading
Once the unloading lid opens and a container is placed below the waste drawer, the operator pulls out the drawer and emties the sterile waste into the container.
As the container is pulled away, the lower lid closes and the sterilizer automatically starts the next cycle.
GENERAL FEATURES
Technical Features | Value |
Size (L x W x H) (mm) | 2700x1600x1600 |
Weight (Kg) | 2680 |
Air Pressure (Bar max) | 8 |
Electrical connection required (Kw) | 30* |
Working Characteristics | Value |
Sterilizing Capacity (Kg/ Hour) | 25-35 |
Process Volume Capacity (Lt.) | 150 |
Average Waste Density (Kg/m3) | 100 - 150 |
Average Cycle Time (Min.) | 30 |
Maximum Steam Flow (Kg/Hour) | 140 |
Sterilization Efficiency (SAL) | 8 Log10 |
Consumption / Cycle | Value |
Steam (Kg) | 7 |
Electricity (Kw) | 1.5** |
Water (Lt) | None*** |
Special Consumables | None |
* P50 – P100 – P150 includes built in electrical steam boiler
** Electrical consumption of the sterilizer only
*** Water consumption of integrated steam boiler: 7 – 12 Lt./ Cycle
All Systems can be customized to customer specification